PROFIBUS communication
Parameterising technology modules
RS485 interface − EPM−S650
l
477
EDSIO1000 EN 7.0
Parameter data 3964(R) protocol
Lenze
Description/value
Name
Data set
Lenze
Description/value
Name
Byte
No.
80
h
0
Baud rate
00
h
: 9600 Baud
01
h
: 150 Baud
02
h
: 300 Baud
03
h
: 600 Baud
04
h
: 1200 Baud
05
h
: 1800 Baud
06
h
: 2400 Baud
07
h
: 4800 Baud
08
h
: 7200 Baud
09
h
: 9600 Baud
0A
h
: 14400 Baud
0B
h
: 19200 Baud
0C
h
: 38400 Baud
0D
h
: 57600 Baud
0E
h
: 76800 Baud
0F
h
: 115200 Baud
10
h
: 109700 Baud
00
h
1
Protocol
The protocol to be used. This setting influences the
structure of the parameter data.
03
h
: 3964
03
h
: 3964R
03
h
2
Data format
Bit 1/0 number of data bits
00
b
: 5
01
b
: 6
10
b
: 7
11
b
: 8
Bit 3/2 parity
00
b
: none
01
b
: odd
10
b
: even
11
b
: even
Bit 5/4 number of stop bits
01
b
: 1
10
b
: 1.5
11
b
: 2
Bit 7/6 flow control
00
b
: None
01
b
: Hardware
10
b
: XON/XOFF
13
h
3
ZNA
Time delay after command; waiting time to be
complied with until the next transmit request is
executed.
0 ... 65535 [20−ms steps] (00
h
.:. FF
h
)
00
h
4
Character delay time
Character delay time; the character delay time defines
the max. permissible interval between two received
characters within a frame. If the character delay time is
0, the module independently calculates the character
delay time on the basis of the baud rate (approx. the
double character time).
0 ... 65535 [20−ms steps] (00
h
.:. FF
h
)
0Ah
5
Acknowledgement time
The acknowledgement time defines the max.
permissible interval until the partner is acknowledged
while establishing/terminating a connection.
0 ... 65535 [20−ms steps] (00
h
.:. FF
h
)
0A
h
6
Block wait time
Maximum time between the recognition of a
requested frame (DLE) and the response.
0 ... 255 [ms] (00
h
... FF
h
)
0A
h
7
STX repetitions
Maximum number of times the module attempts to
establish a connection.
0 ... 255 [ms] (00
h
... FF
h
)
05
h