Product description

I/O compound modules − counter

One counter 32 bits, 24 V DC − EPM−S600

3

l

165

EDSIO1000 EN 7.0

Counting periodically

A) No main counting direction:

Limits

Counting range

Lower counting limit

−2 147 483 648 (−2

31

)

Upper counting limit

+2 147 483 647 (2

31

−1)

Function:

ƒ

For starting the counting process the internal gate has to be opened.
– The counter counts forwards from the loading value or backwards in the counting

range.

– If there is an overflow or underflow at the respective counting limit, the counter

skips to the loading value and continues to count from there.

ƒ

For stopping the counting process the internal gate has to be closed.

Upper counting

limit value

Loaded value

0

Counter starts

Time

Counter content

Lower counting

limit value

Overflow

Underflow

Zero crossing

Counter stops

SLIO035

Fig. 3−47

Example of "Counting periodically" and no main counting direction