Product description, Technical data – Lenze I/O system 1000 System Manual User Manual
Page 150

Product description
I/O compound modules − temperature measurement
Four (two) analog inputs for resistance tests − EPM−S404
l
150
EDSIO1000 EN 7.0
Technical data
EPM−S404: Rated data
Module identifier
1030
dec
Current consumption/power loss
Current consumption from backplane bus
75 mA
Power loss
1 W
Analog inputs
Number of inputs
4
Cable length
shielded
200 m
Load voltage
Nominal value
DC 24 V
Current consumption from load voltage
L+
30 mA (without load)
Resistor inputs
Resistance ranges
0 ... 60
W
0 ... 600
W
0 ... 3000
W
Operational error limit
± 0.4 %
Basic error limit
± 0.2 %
Resistance thermometer inputs
Resistance thermometer ranges
Pt100
Pt1000
Ni100
Ni1000
Operational error limit
± 0.4 %
Basic error limit
± 0.2 %
Measuring principle
Sigma−delta
Resolution
16 bits
Basic conversion time
4.2 ... 324.1 ms (50 Hz) per channel
3.8 ... 270.5 ms (60 Hz) per channel
Interference voltage suppression for a
frequency of
> 80 dB at 50 Hz (UCM < 60 V)
Destruction limit (input voltage)
9 V
Temperature error
(relating to input range)
± 0.005 %/K
Linearity distortion
(relating to input range)
± 0.005 %
Repeat accuracy (in steady−state vibration at
25°C, relating to the input range)
± 0.05 %
Input data size
8 bytes
Status, alarm, diagnostics
Status display
Yes
Alarms
Yes, parameterisable
Process alarm
Yes, parameterisable
Diagnostic alarm
Yes, parameterisable
Diagnostic function
Yes
Diagnostic information can be read out
Possible
Module status
Green LED
Module error display
Red LED
Channel error display
Red LEDs per channel