Product description

I/O compound modules − communication
RS232 interface − EPM−S640

3

l

222

EDSIO1000 EN 7.0

Technical data

Rated data EPM−S640

Module identifier

3585

dec

Current consumption/power loss

Current consumption from backplane bus

100 mA

Current consumption from load voltage L+

10 mA (without load)

Power loss

1 W

Status, alarm, diagnostics

Status display

Yes

Alarms

Yes, parameterisable

Process alarm

No

Diagnostic alarm

Yes, parameterisable

Diagnostic function

Yes, parameterisable

Diagnostic information can be read out

Possible

Module status

Green LED

Module error display

Red LED

Channel error display

Red LED

Communication

Interface

RS232

Electrical isolation

To the backplane bus

PtP communication

Yes

Transmission speed

150 bps ... 115.2 kbps

Cable length, max.

15 m

Input data for bus coupler module

EPM−S110

8 bytes

EPM−S120

8/20/60 bytes (selectable)

EPM−S140

20/60 bytes (selectable)

EPM−S130, EPM−S150, EPM−S160

60 bytes

Output data for bus coupler module

EPM−S110

8 bytes

EPM−S120

8/20/60 bytes (selectable)

EPM−S140

20/60 bytes (selectable)

EPM−S130, EPM−S150, EPM−S160

60 bytes