beautypg.com

Product description – Lenze I/O system 1000 System Manual User Manual

Page 225

background image

Product description

I/O compound modules − communication

RS485 interface − EPM−S650

3

l

225

EDSIO1000 EN 7.0

Overview

2

6

3

7

4

8

1

5

EPM-S650

DC24V

Term

Term

0V

TxD+

TxD-

RxD-

RxD+

GND

RTS

1

0

CP

SLIOS650

Fig. 3−78

Elements and circuit diagram

0

Displays for module status

1

Terminals

1...8

Connection number

Status displays

Module status LEDs

0

View

Pos.

Designation

Colour

Explanation

1

10

1

RUN

Green

On: Module is ready for operation

2

MF

Red

On: Module error (see table below)

3

TxD

Green

On: Transmit data

4

RxD

On: Receive data

5

IF

Red

Blinking: Line interruption, overflow, parity error,
or character frame error

6

Not assigned

7

8

9

SLIO001

10

Messages of the status LEDs RUN and MF

RUN

MF

Meaning

On

Off

Module status OK
Bus communication is OK

On

On

Module reports error
Bus communication is OK

Off

On

Module reports error
Bus communication not possible

Off

Off

Error in the bus supply voltage

Blinking

Blinking

Configuration error (

^ 249)