DeviceNet communication

Access to the I/O system 1000
Access to diagnostic data

11

l

562

EDSIO1000 EN 7.0

11.2.3

Access to diagnostic data

The DeviceNet bus coupler exclusively supports passive diagnostics, i.e. no alarm
activation on the module side is required for diagnostics. You have to request the
diagnostics by yourself.

For this purpose, go to your configuration tool and select the diagnostic data of the
corresponding DeviceNet slot. All diagnostic data of the module will be displayed as byte
sequence.

DeviceNet bus coupler

Class code: 100 (64

h

)

No.

Name

Information

Format

Example

1

DeviceName

Device name

String

EPM−S150

2

HwVersion

HW output version

String

02

3

SwVersion

SW output version

String

V101

4

SerialNumber

Serial number

Unsigned16,
String

00000205

5

FpgaVersion

FPGA version

Unsigned16,
String

V208

6

MxFile

Mx file

String

MX000053.101

7

ProductVersion

Product version

String

01V01.00

8

OrderCode

Order no.

String

(8−digit Lenze material
number)

I/O compound module

Class code:

Slot 1: 101 (65

h

)

Slot 2: 102 (66

h

)

...

Slot 64: 164 (A4

h

)

No.

Name

Information

Format

Example

1

DeviceName

Device name

String

EPM−S403

2

HwVersion

HW output version

String

21

3

SwVersion

SW output version

String

V202

4

SerialNumber

Serial number

Unsigned32,
String

00001143

5

FpgaVersion

FPGA version

Unsigned16,
String

V208

6

MxFile

Mx file

String

MX000028.130

7

ProductVersion

Product version

String

01V31.001

8

OrderCode

Order no.

String

(8−digit Lenze material
number)

20

Parameter

Parameter data

String

x00 x00 x31 x31 x31 x31

21

Diagnostics

Diagnostic data

String

x00 x15 x00 x00
x73 x08 x04 x00
x00 x00 x00 x00
x00 x00 x00 x00
4x000020EB