4 storage of the pdos, Ethercat kommunikation – Lenze I/O system 1000 System Manual User Manual
Page 553
EtherCAT Kommunikation
Diagnostics
Storage of the PDOs
l
553
EDSIO1000 EN 7.0
IMPORTANT
Possible settings
Designation
Index
Selection
Lenze
0x5000
h
If object 0xF100 indicates that a
process alarm has occurred, you
can access the current process
alarm data here. The
corresponding module
description contains the process
alarm data assignment.
0 Hardware
interrupt data
Current process alarm data
1 Slot number
EtherCAT slot no. of module on
which the alarm has occurred
2 Hardware
interrupt data
00
Process alarm data
3 Hardware
interrupt data
01
4 Hardware
interrupt data
02
5 Hardware
interrupt data
03
6 Acknowledge
Writing any value resets the
process alarm counter and if
necessary acknowledges the
alarm
If auto−acknowledge is
deactivated for the EtherCAT
coupler, you can reset the
hardware interrupt counter of
object 0xF100 and acknowledge
the process alarm by writing any
value to subindex 0x06 of index
0x5000.
10.12.4
Storage of the PDOs
Index
Description
0x6000
Input PDO (1. slot)
0x6001
Input PDO (2. slot)
...
...
0x601F
Input PDO (32. slot)
0x7000
Output PDO (1. slot)
0x7001
Output PDO (1. slot)
...
...
0x701F
Output PDO (32. slot)