12. Refer to the Statistics field to set the following data:
13. Select OK to save the changes and overrides made to the RF Domain configuration. Selecting
Reset reverts the screen to its last saved configuration.
14. Select Sensor Configuration from within the expanded RF Domain Overrides menu.
FIGURE 19
Sensor Configuration Override screen
15. Define a Sensor Configuration for dedicating a WIPS server resource for client terminations
and WIPS event logging.
Optionally set up to 3 overrides for the listed device’s sensor server assignment:
NOTE
A blue override icon (to the left of a parameter) defines the parameter as having an override applied.
To remove an override go to the Basic Configuration section of the device and click the Clear
Overrides button. This removes all overrides from the device.
Window Index
Use the spinner control to set a numerical index used as an identifier for RF Domain
statistics.
Sample Interval
Use the spinner control to define the interval (in seconds) to capture windowed
statistics supporting with the listed RF Domain. The default is 5 seconds.
Window Size
Use the spinner control to set the number of samples used to define RF Domain
statistics. The default value is 6 samples.
Server Id
Use the spinner control set a numerical index to differentiate this server from
other servers. Up to 3 sensor server resources can be defined. Select + Add Row
as needed to add additional servers.
IP Address/Hostname
Set IP Addresses or Hostnames of up to 3 sensor servers supporting WIPS events
on behalf of the controller or service platform.
Port
Assign the sensor server port number using the spinner control. The default port is
443.