3. Conduct the following array diagnostic operations from within the RAID Manage Array field:
4. Conduct the following drive diagnostic operations from within the RAID Manage Drive field:
5. Select Execute to initiate the selected command from either the RAID Manage Array or RAID
Manage Drive fields.
To view the service platform’s current RAID array status, drive utilization and consistency
check information, refer to
.
silence
Select silence to stop (silence) the service platform’s RAID controller array alarm. When a drive is
rendered offline for any reason, the service platform’s array controller alarm is invoked.
locate-stop
Select locate-stop to stop the LEDs of all the drives within the array.
check-start
Select check-start to initiate a consistency check on the RAID array.
remove
Select remove to prepare a selected drive for physically removing it from the drive array. The
remove command can be applied to either an online or hot spare drive.
install
Once a new drive is installed, it must be prepared for active array utilization. Select install to
dedicate a selected drive to repair a degraded array and begin an array rebuild operation.
spare
Select spare to define a selected unused drive as a hot spare that can be dedicate as an active
array drive if one of the two online array drives were to fail.
locate
Select locate to flash a selected drive’s LED so it can easily located within the drive array.