Allied Telesis AT-S62 User Manual
Page 477

AT-S62 User’s Guide
Section VI: Port Security
477
The Configure Authenticator Port Access Parameters menu is shown
in Figure 159.
Figure 159 Configure Authenticator Port Access Parameters Menu
6. Select the parameter you want to modify. The parameters are
described below:
1 - Port Control
This parameter can take the following values:
❑ Force-authorized: Disables IEEE 802.1X port-based
authentication and causes the port to transition to the authorized
state without any authentication exchange required. The port
transmits and receives normal traffic without 802.1x-based
authentication of the client. This is the default setting
❑ Force-unauthorized: Causes the port to remain in the
unauthorized state, ignoring all attempts by the client to
authenticate. The switch cannot provide authentication services
to the client through the interface
❑ Auto: Enables 802.1x port-based authentication and causes the
port to begin in the unauthorized state, allowing only EAPOL
frames to be sent and received through the port. The
authentication process begins when the link state of the port
changes or the port receives an EAPOL-Start packet from a
supplicant. The switch requests the identity of the client and
begins relaying authentication messages between the client and
the authentication server. Each client that attempts to access the
network is uniquely identified by the switch using the client's
MAC address.
Allied Telesyn Ethernet Switch AT-8524M - AT-S62
Production Switch
User: Manager
11:20:02 02-Jan-2004
Configure Authenticator Port Access Parameters
Configuring Port 3
1 - Port Control ............. Auto
2 - Quiet Period ............. 60 Seconds
3 - TX Period ................ 30 Seconds
4 - Reauth Period ............ 3600 Seconds
5 - Supplicant Timeout ....... 30 Seconds
6 - Server Timeout ........... 30 Seconds
7 - Max Requests ............. 2
8 - Control Direction ........ INGRESS
R - Return to Previous Menu
Enter your selection?