6. To set the load distribution method, type 3 to toggle the selection
through the following possible settings:
❑ SRC MAC - Source MAC address
❑ DST MAC - Destination MAC address
❑ SRC/DST MAC - Source address /destination MAC address
❑ SRC IP - Source IP address trunking
❑ DST IP - Destination IP address trunking
❑ SRC/DST IP - Source address /destination IP address
The default is SRC/DST MAC. For background information, refer to
Load Distribution Methods on page 123.
7. Type 4 to select Trunk Ports and, when prompted, enter the ports of
the trunk. A trunk can contain up to eight ports. You can identify the
ports individually (for example, 3,7,10), as a range (for example, 5-11),
or both (for example, 2,4,11-14).
8. Type C to select Create Trunk.
The port trunk is now active on the switch.
9. After making changes, type R until you return to the Main Menu. Then
type S to select Save Configuration Changes.
10. Configure the ports on the remote switch for port trunking.
11. Connect the cables to the ports of the trunk on the switch.