Hardware Installation
2−27
VM 3000 Installation and Operating Manual
DATATEK D−2000/2166 CONNECTIONS
The VM 3000 can be connected to a Datatek D−2166 Buffer Control Module, which in turn is connected to a D−2000 Series
routing switcher (see page 2−27). The protocol setting is: 38400 baud, 8 data bits, even parity, 1 stop bit.
Although the VM 3000 is connected to one of the D−2166 Buffer Control Module ports labelled “RS−232,” the port must
be set with an internal jumper to operate according to RS−422. Refer to the manual supplied with the D−2166 for more infor-
mation.
Figure 2−32. Connection to Datatek D−2166 Buffer Control Module.
See Figure 2−33 for a description of this cable
Datatek protocol
“RS−232−C A” or
“RS−232−C B” port
jumpered for RS−422 operation
to D−2000 series routing switcher
D−2167 Buffer Interface and
D−2166 Buffer Control Module
in DF−2115 Rack Frame
VM 3000
LAN
See pg
House time
code
(optional).
See pg.
Odd serial port
Figure 2−33. Cable for connecting VM 3000
to Datatek D−2166 Buffer Control Module.
1
6
R−
2
7
3
T−
8
4
9
5
T−
R+
to VM 3000
serial port
to Datatek D−2166/DF−2115
“RS−232−C A” or “RS−232−C B” port
jumpered for RS−422 operation. Refer
to the manual supplied with the Datatek
router for more information.
G
Ground
R−
Receive minus
R+
Receive plus
T+
Transmit plus
T−
Transmit minus
DB9P
(male)
= twisted pair
T+
R−
R+
G
G
T+