Hardware Installation

2−27

VM 3000 Installation and Operating Manual

DATATEK D−2000/2166 CONNECTIONS

The VM 3000 can be connected to a Datatek D−2166 Buffer Control Module, which in turn is connected to a D−2000 Series
routing switcher (see page 2−27). The protocol setting is: 38400 baud, 8 data bits, even parity, 1 stop bit.

Although the VM 3000 is connected to one of the D−2166 Buffer Control Module ports labelled “RS−232,” the port must
be set with an internal jumper to operate according to RS−422. Refer to the manual supplied with the D−2166 for more infor-
mation.

Figure 2−32. Connection to Datatek D−2166 Buffer Control Module.

See Figure 2−33 for a description of this cable

Datatek protocol

“RS−232−C A” or

“RS−232−C B” port

jumpered for RS−422 operation

to D−2000 series routing switcher

D−2167 Buffer Interface and
D−2166 Buffer Control Module
in DF−2115 Rack Frame

VM 3000

LAN

See pg

2−46

House time

code

(optional).

See pg.

2−110

Odd serial port

Figure 2−33. Cable for connecting VM 3000
to Datatek D−2166 Buffer Control Module.

1

6

R−

2

7

3

T−

8

4

9

5

T−

R+

to VM 3000

serial port

to Datatek D−2166/DF−2115

“RS−232−C A” or “RS−232−C B” port

jumpered for RS−422 operation. Refer

to the manual supplied with the Datatek

router for more information.

G

Ground

R−

Receive minus

R+

Receive plus

T+

Transmit plus

T−

Transmit minus

DB9P

(male)

= twisted pair

T+

R−

R+

G

G

T+