beautypg.com

Grass Valley VM 3000 System Controllers v.7.4 User Manual

Page 758

background image

Glossary−10

sticky levels − control panel

BREAKAWAY

operation during which the selected

LEVELS

remain selected after a Take.

Sundance − engineering project name for

CM

4000/ACCUSWITCH

.

super crosspoint bus − see

CROSSPOINT

BUS

.

super party line − see

PARTY

LINE

.

TCP/IP address − a computer address consisting of four decimal integers separated by periods. Each integer

represents eight bits of an IP address. Compare with

HARDWARE

ADDRESS

.

TCS 1 −T

ELEMATION

Control System. Predecessor to

BCS

3000

and Jupiter. TCS 1 provides machine control only

(no switcher control).

TCS 2 − control panel protocol used with the MCS 2000 Master Control Switcher. Contains byte counts, check

sums, and error detection. Replaces the TCS CP interface but not the TCS MI interface. TCS2 can only be used
with the MCS 2000, which must be equipped with updated PROMs.

TeleMation − Salt Lake City manufacturer of CATV and broadcast equipment founded by Lyle Keys and

associates in 1963. Now part of Grass Valley.

three−stage switching − architecture used for very large switchers as a means of reducing crosspoints needed for

a given number of inputs/outputs. An array of relatively small matrixes is arranged in an input stage, an inter-
mediate stage, and an output stage. The path taken by a given signal through these stages is determined by
software and will vary according to which circuits are already in use. Unlike

PATH

FINDING

between two dis-

crete switchers, three−stage switchers are carefully designed so that all inputs are always available at all out-
puts; i.e., the switcher cannot be blocked.

tie line − see

PATH

FINDING

.

tributary − term used in

ESBUS

documentation for an intelligent device (such as a VTR or control panel) con-

nected to an

ESBUS

.

VDE − Verband Deutscher Electrotechniker e.V. (Union of German Electrical Engineers). Professional organiza-

tion in Germany authorized to conduct product safety tests.

VITC − Vertical Interval Time Code, embedded in the vertical interval of the video signal.

VGA Status Display − built−in switcher and machine control status display feature of the VM 3000. Can be

controlled by front−panel buttons or with optional VC 3020 panel.

VM 3000B − VM 3000 with minor electrical changes and “crescent” style front panel. Functionally identical to

VM 3000.

WPE − serial device type designation used for SPQ 3A frequency response equalizer connection to VM 3000.

XPT − crosspoint.

X−Y selection method − full−matrix control of switcher, where source is described as (x) and destination is

described as (y).

This manual is related to the following products: