Control Panel Operation

CP 3832L / 3864L

6−118

VN 3000 Installation and Operating Manual

SINGLE−BUS OPERATION

32

sources

(green)

Figure 6−147. CP 3832L.

64

sources

(green)

Figure 6−148. CP 3864L.

Each input button of the CP 3832L / 3864L can be assigned to a specific source using a CP Input set (page 5−71.) The name
of this set, and the name of the destination to be controlled, is entered on the MPK Devices table (page 5−112 and following).

To verify destination (CP 3864L only) − On the CP 3864, the destination is always shown in the “Destination” window.

Audio−follow−video switching − When one of the input buttons is pressed, a Take* command is issued to all levels of the
switcher matrix. A status* signal is then returned to the control panel; this confirms the action by lighting the selected input
button and displaying the name of the input in the Current window.

Split switching − When the operator desires to take only specific switcher levels, those levels are defined by first pressing
one or more of the six level breakaway buttons. The Take command to the switcher will be executed when an input button
is pressed. The switcher will confirm the action by lighting the selected input button. Since the panel always operates in
“sticky level” mode, the selected level buttons will remain lit after the input button has been pressed.

Split statusing − To status a specific level of a previous breakaway level switch, select the level to be statused; one of the
input buttons will illuminate and the Current window will indicate the source for that level. If more than one level status button
has been toggled on (like A1 and A2), only the lowest level (A1) will be statused.

* Defined in Glossary Section