beautypg.com

This is a 12−category panel. go to step 10 – Grass Valley VM 3000 System Controllers v.7.4 User Manual

Page 275

background image

Configurator

CP Input Set

5−65

VM 3000 Installation and Operating Manual

VTR

CG

NET

SAT

A

VCR

CAM

REM

EJ**

B

FILM

PTCH

STU

FS

C

AUX

TEST

MISC

SS

D

**EMER on CP 3800

b.

Specify the desired Entry (unit) number. This can be done by clicking on the desired “Entry” field and typing in
the number. Press ENTER.

Guidelines for using the editor are found on page 5−3.

Note: For an input that is heavily used, an entry number of zero can be specified to help speed up control
panel operation. For example, by assigning color bars as “Test 0,” the mnemonic for color bars will ap-
pear immediately on the control panels whenever “Test” is selected; the operator can then complete the
switch by pressing Take. However, for this to work properly the zero entry must appear in this table
before all other entries for that category; for example, “Test 0” must appear before “Test 1,” “Test 2,”
etc.

c.

Select the Input name.

The source for the input names is the Switcher Input table (page 5−44).

d.

Check the Auto Mnemonic box or enter the desired Mnemonic.

The Auto Mnemonic function can be used to enter a control panel mnemonic automatically based on the Name
given to the input. In cases where the input Name is more than four characters long, the mnemonic will be truncated
to the first four characters.

If an input Name is changed on the Switcher Input table and Auto Mnemonic is enabled, the mnemonic will change
to the new name automatically.

Note: if you use the Auto Mnemonic feature, it will not work if you go back to a version of the Jupiter
editor prior to 6.2.1.

Remember that a CP 3000 and CP 3030 panel can display four−character mnemonics, while the CP 3008 and CP
3800 can display eight−character mnemonics.

When finished, skip to Step 17.

10.

CP 320, CP 328, CP 3808, CP 3824, CP 3830, CP 3830P

a.

Enter the desired Category. This can be done by double−clicking on the appropriate field in the Category column;
this will open a pull−down menu of categories. Click on a category and press ENTER.

The 16−category factory default set used for the CP 3808 panel is as follows:

Default sets may vary —
confirm by creating a new set!

VTR

CAM

SAT

EJ

VCR

NET

REM

FILM

Studio

MISC

AUX

FS

CGEN

TEST

PTCH

STILL

This manual is related to the following products: