Configurator

CP Input Set

5−64

VM 3000 Installation and Operating Manual

For Grass Valley GVG−200 applications, select E−MEM. clicking on “Apply” and “Open Table” will open a
blank version of the table shown in Figure 5−45. Go to Step 14.

For Philips Broadcast Automation or other external computer applications, a type “serial” table will be
required. Click on “Apply” and “Open Table” to open a blank version of the CP table without a “Mnemonic”
column. Skip to Step 15.

For CP 3832 or CP 3864 control panels (including type “L”), a type “cp3832” table will be required. Click on
“Apply” and “Open Table” to open a blank version of the CP table. Then skip to Step 16.

7.

If you click on an existing Input Set, this will call up a table similar to that shown in Figure 5−45.

Figure 5−45. Input Set menu (example).

1

Input Set — KXYZ−INP

Category

Entry

Mnemonic

Input

2

3

Test

1

BARS

BARS

VTR

1

VT01

VT01

4

5

Test

2

TONE

TONE

Test

3

CODE

TC

VTR

2

VT02

VT02

VTR

3

VT03

VT03

VTR

4

VT04

VT04

VTR

5

VT05

VT05

MISC

8

ESS

ESS

6

7

8

n

Auto

Mnem

Logical

8.

If you are:

— Adding a new entry, click on the row number above where you want the new entry to appear. Click the “Edit”

pull−down menu. Click on “Insert” and make the addition. Then go to Step 9 through 15 below as appropriate.

Important: Row numbers on Jupiter tables are used as the “logical” numbers for destinations. Changing
the row number of a destination (by inserting/deleting a new output in the middle of the table, for example)
will disrupt control of the system, requiring controller boards to be memory−cleared and reset (see “Clear-
ing Battery−Protected Memory” in Appendix B). One way to avoid this interruption is to add new outputs
at the end of tables.

— Editing an existing entry, click on the item you want to change. Then go to Step 9 through 15 below as

appropriate.

9.

CP 2002, CP 3000, CP 3008, CP 3030, CP 3800

a.

Select the desired Category from the pull−down menu. Then press TAB.

The 20−category factory default set used for CP 2002, CP 3000, CP 3008, CP 3030, and CP 3800 panels is as fol-
lows: