beautypg.com

Vde emi/rfi modifications to serial data cables, Power surge protection using jup-485-sup module, Sync reference cables – Grass Valley VM 3000 System Controllers v.7.4 User Manual

Page 182: Time code connections, Power surge protection using jup−485−sup module, Pg. 2−110, Witching. see pg. 2−110

background image

Hardware Installation

2−110

VM 3000 Installation and Operating Manual

VDE EMI/RFI Modifications to Serial Data Cables

User−supplied serial data cables for VDE installations require a ferrite core over each end of the cable, adjacent to the connec-
tor.

Figure 2−125. Serial data cable VDE modifications.

Type 43 material

0.250 inch (6.35 mm) inside diameter

0.95 inch (24.13 mm) length (or longer)

Type 43 material sources

Fair−Rite, part no. 2643480002

Fair−Rite Products Corp., P.O. Box J, Commercial
Row, Wallkill, NY 12589, USA; Tel. (914) 895−2055.

Chomerics, part no. 83−10−A636−1000

Chomerics Inc., 77 Dragon Ct., Woburn, MA 01888
USA; Tel. (617) 935−4850.

Power Surge Protection using JUP−485−SUP Module

Voltage surges may occur in mobile van environments or other applications involving long serial cable runs or cases where
there is a possibility of a power spike appearing between the System Controller and a Jupiter control panel. The
JUP−485−SUP module, available as an option, connects to the VM serial port and uses an internal diode array to limit the
voltage on each of the RS−422/485 conductors to approximately eight volts. For more information, refer to Field Modification
Note 0750790xx or contact Grass Valley Technical Support.

Sync Reference Cables

A video reference (sync) signal should be connected to each Jupiter controller board (including the VM 3000 System Control-
ler, SI 3000 System Controller, and VG 3000 Video Display / Status Generator).

This signal may be color black or composite sync with an amplitude between 1 V P−P and 4 V P−P.

The VM 3000 System Controller must have a sync reference in order for a Grass Valley Crosspoint Bus router to switch during
the house vertical interval. Crosspoint Bus routers are listed on page 2−3.

Time Code Connections

Time code can be connected to a VM 3000, in which case the VM 3000 clock and the file server clock will automatically
synchronize to the time code source.