Hardware Installation
2−128
VM 3000 Installation and Operating Manual
Note 1: When controlled by Jupiter, SlimLine units display green characters, red tally indicators, and one tally level
only. With the Universal Display, only the triple display mode is supported (i.e., 3 segments of 8 characters each,
plus tally indicators).
Note 2: Because the Cat 5 Ethernet cable connecting the controller to the UMDs carries power, the maximum rec-
ommended length is 15 m (50 ft). This is a standard (pin−for−pin) Ethernet cable, not a crossover cable
Note 3: The RP 1/2/3 and RP 1/2/3 C series UMDs (which are no longer available) are installed and configured
similarly to the SlimLine series. The main difference is that the RP 1/2/3 units are daisy−chained directly to a VM/
SI 3000 serial port.