Cp level set, Level set, Input set – Grass Valley VM 3000 System Controllers v.7.4 User Manual
Page 265: Output set, Override set, Sequence set, Category set, Mpk devices

Configurator
CP Level Set
5−55
VM 3000 Installation and Operating Manual
CP Level Set
1
CP Level Set — KXYZ−LVL
Mnemonic
Level
Break
Switch
2
3
VID
VIDEO (MAINROUT)
LEFT
LEFT (MAINROUT)
RGHT
RIGHT (MAINROUT)
4
TC
TC (MAINROUT)
Figure 5−38.
Figure 5−39.
Password
Network Description
Switcher Description
Control Panel Sets
Level set
Input set
Machines
TCS−1 Device Codes
Status Display Header
Tally
Exclusion
The CP Level Set table is used to assign levels to control panels. In most cases, control panels are allowed to control all levels,
but creating multiple CP Level Sets allows restricting control to certain levels. Level Sets are assigned to individual control
panels on the MPK Devices table (page 5−109).
Selecting “Control Panel Sets” on the configuration set table list (Figure 5−15 on page 5−20) will open a dialog similar to
that shown in Figure 5−38. This dialog can be used to create, open, copy, and delete Control Panel sets. A example of a com-
pleted CP Level Set table is shown in Figure 5−39.
When creating a name for a Jupiter set, it’s a good practice to use letters and numbers only. If you want to use punctuation
or special characters, check the list on page 5−7 before creating a name.
When creating a new set, you will asked for the set type: “CP 3000” (for four−character display panels), or “CP−3800” series
(for most eight−character display panels).