beautypg.com

Single bus control (“cp 3810l”), Figure 5−118 – Grass Valley VM 3000 System Controllers v.7.4 User Manual

Page 347

background image

Configurator

MPK Devices

5−137

VM 3000 Installation and Operating Manual

Single Bus Control (“CP 3810L”)

In the example shown in Figure 5−118, a CP 3832 is used to select inputs and a CP 3810 is used to control the individual levels
of one output. The CP 3810 can thus be used for breakaway switching.

The corresponding MPK table entries are shown in Figure 5−119.

MPK bus

VM 3000
“VM1”

CP 3832

“CP3832”

CP 3810

“CP3810”

32

sources

Levels for 1

destination

Figure 5−118.

CP3832

CP−3832

2

00000043

3832−IN

VT01

CP3810

CP−3810L

2

00000044

CP3832

1

MPK Devices

MPK

Expansion

Pass

Board

VM1

Port

Address

Input Sets

Output Sets

Level Set

Overide Set

Sequence Set

2

VM1

KXYZ−LEV

Devices

word

In Panel

Out Panel

KXYZ−LEV

Figure 5−119. Entry for system shown in Figure 5−118.

Device

Type

Notice that the Expansion boxes for both panels are unchecked.

Main panel entries — In this example, a CP 3832 is the “main” panel and is therefore assigned specific CP sets. In the “Input
Set” column, enter the name of the CP Input Set that will be used to assign inputs to the main panel (for more information
about CP Input Sets, see page 5−58). In the “Output Set” column, enter the name of the output that will be controlled.

Note: Even when associated with a CP 3810, the Main panel is still configured independently and can be operated
independently. In this example, the CP 3832 will operate as a single−bus control panel (because Expansion = No).

For the CP 3810, select Device Type “CP−3810L.” Enter the name of the Main panel in the Input Set column.

For operating instructions, see page 6−126.