Single bus control (“cp 3810l”), Figure 5−118 – Grass Valley VM 3000 System Controllers v.7.4 User Manual
Page 347

Configurator
MPK Devices
5−137
VM 3000 Installation and Operating Manual
Single Bus Control (“CP 3810L”)
In the example shown in Figure 5−118, a CP 3832 is used to select inputs and a CP 3810 is used to control the individual levels
of one output. The CP 3810 can thus be used for breakaway switching.
The corresponding MPK table entries are shown in Figure 5−119.
MPK bus
VM 3000
“VM1”
CP 3832
“CP3832”
CP 3810
“CP3810”
32
sources
Levels for 1
destination
Figure 5−118.
CP3832
CP−3832
2
00000043
3832−IN
VT01
CP3810
CP−3810L
2
00000044
CP3832
1
MPK Devices
MPK
Expansion
Pass
Board
VM1
Port
Address
Input Sets
Output Sets
Level Set
Overide Set
Sequence Set
2
VM1
KXYZ−LEV
Devices
word
In Panel
Out Panel
KXYZ−LEV
†
Figure 5−119. Entry for system shown in Figure 5−118.
Device
Type
Notice that the Expansion boxes for both panels are unchecked.
Main panel entries — In this example, a CP 3832 is the “main” panel and is therefore assigned specific CP sets. In the “Input
Set” column, enter the name of the CP Input Set that will be used to assign inputs to the main panel (for more information
about CP Input Sets, see page 5−58). In the “Output Set” column, enter the name of the output that will be controlled.
Note: Even when associated with a CP 3810, the Main panel is still configured independently and can be operated
independently. In this example, the CP 3832 will operate as a single−bus control panel (because Expansion = No).
For the CP 3810, select Device Type “CP−3810L.” Enter the name of the Main panel in the Input Set column.
For operating instructions, see page 6−126.
†
Data not used, but entry must be present to satisfy compiler.