The table. then skip to step 12, Skip to step 13 – Grass Valley VM 3000 System Controllers v.7.4 User Manual
Page 295
Configurator
CP Output Set
5−85
VM 3000 Installation and Operating Manual
e.
Optionally, enter the Level Set name.
The Level Set column should be used when multiple switchers are in the system and you want the control panels
to control and status more than one switcher. See page 5−97.
f.
Optionally, enter a Button number.
By entering a CP 3809 Expansion Panel button number from 1 to 40 (8 buttons x 5 panels max) in the Button
column and appropriate row of the CP Output table, the output will be assigned permanently to the desired button.
Note that this CP Output table must be assigned to the main panel (CP 3808 or CP 3830) on the MPK Devices
table—page 5−109. (Dynamic assignment of outputs, using the front panel, is described on page 6−124.)
11.
CP 310 24 x 8 Eight−Bus Control Panel
For the eight−bus CP 310 control panel, a special CP Output Set is used to identify the eight outputs that will be con-
trolled by the panel. This set is assigned to the specific CP 310 with the MPK devices table. In this case, there must still
be an entry in each field of the CP Output Set table, even though the only data that will be used is in the Output column.
The category name “dflt” is used throughout, but selection numbers and at least one character for a mnemonic will have
to be entered on each of the eight rows in order to satisfy the system compiler.
When finished, skip to Step 20.
12.
CP 330 operating in dual bus mode
For the dual−bus CP 330 control panel, a special CP Output Set is used to identify the two outputs that will be controlled
by the panel. This set is assigned to the specific CP 330 with the MPK Devices table. The only data that will be used
is in the Output column; however, category names, selection numbers, and at least one character for a mnemonic will
have to be entered on both rows in order to satisfy the system compiler.
When finished, skip to Step 20.
13.
MC 3020D Delegate Panel
The content of these tables will depend on whether an MC 3020D is assigned to each machine; or, whether a single MC
3020 equipped with expansion panel(s), located in a central control panel cluster, is used to delegate up to 80 machines.
Panel−per−machine. When a separate MC 3020D is located next to each machine, a separate Output Set is created for
each panel. Each Output Set lists the name of the associated machine (Figure 5−63). The name of each MC 3020D Out-
put Set is then entered on the MPK Devices table (Figure 5−141 on page 5−162).
1
Output Set — VT01−OUT
Machine Name
VT01
2
Figure 5−63. CP Output Set used to establish a machine
name for panel−per−machine MC 3020D (example). The
corresponding system is shown on page 5−161.