Connection to Multiple Distribution Switchers with Path Finding

Note: Data level pathfinding is not supported.

The path finding software option allows two or more Jupiter−controlled routing switchers to operate as a system, where one
switcher can access the other’s inputs through a number of tie lines. Tie lines can vary in number from one switcher to another,
and from one level to another.

Two wiring schemes can be used: sequential wiring, where tie lines are organized in blocks (as shown on page 2−41); and
non−sequential wiring (as shown on page 2−42). Sequential wiring requires entries to only one file server table (the “Path
finding Data Table,” shown on page 5−194). Non−sequential wiring requires use of an additional table (the “Non−Sequential
Path finding Data Table,” shown on page 5−205.)

SEQUENTIAL PATH FINDING (PATH FINDING USING SEQUENTIAL WIRING)

Connections can start with any input or output number, but thereafter must be sequential. Page 2−41 shows example connec-
tions for one level. Notice that the lowest number in an output group must be connected to the lowest number in the corre-
sponding input group, and so on.

Due to distance limitations of the CC−2010 Matrix cable, it may necessary to install a separate VM 3000 Control Processor
for each switcher.

See page 5−194 for an overview of sequential path finding and software configuration requirements.

NON−SEQUENTIAL PATH FINDING (PATH FINDING USING NON−SEQUENTIAL WIRING)

In some cases, especially when adding tie lines to an existing system, wiring new lines out of sequence may be desirable. Page
2−42 shows example connections for one level.

Due to distance limitations of the CC−2010 Matrix cable, installing a separate VM 3000 Control Processor for each switcher
may be necessary.

See page 5−194 for an overview of path finding and software configuration; then refer to page 5−205 for additional non−se-
quential path finding requirements.