Level breakaways (split switching), Breakaway using override keys (preset off), Figure 6−114 – Grass Valley VM 3000 System Controllers v.7.4 User Manual
Page 501
Control Panel Operation
CP 3824
6−81
VM 3000 Installation and Operating Manual
LEVEL BREAKAWAYS (SPLIT SWITCHING)
Breakaway Using Override Keys (PRESET Off)
2
Figure 6−114.
CURRENT
PRESET
LEVEL
MENU
CLEAR
PROT
PRE−
SET
TAKE
LOCK CHOP
PAGE
SEND
Press LEVEL
1
Press CLEAR
These six buttons now function as temporary
level select keys. Lighted buttons initially indicate
defined levels.
VIDEO
3
2
1
4
5
6
VTR 001
Name of selected Level
shown here
Status shown here
Toggle OFF levels you do not wish to switch.
In this example, Level 1 is toggled OFF. Only
LEFT and RIGHT will switch.
VTR−002
VTR 002
3
Select desired Override input. This completes the switch.
4
To check the switch, press LEVEL. Then press one of the six temporary level keys; status will be
shown in the Current window. Then press CLEAR.
If there are more than six levels, use the UP/DOWN keys to access the second set of six levels,
etc.
CURRENT
PRESET
CURRENT
PRESET
1
2
3
4
VTR
1
VTR
2
VTR
3
VTR
4
5
6
7
8
STU
1
STU
2
EDIT
1
EDIT
2
BLACK
BARS
TONE
SILE
NCE
EBS
1
EBS
2
TEST
1
TEST
2