Configurator

CP Output Set

5−86

VM 3000 Installation and Operating Manual

Central control arrangement. In this application, the MC 3020D Output Set is actually a list of machines and is used
to assign each machine to a particular button of the CP 3021D Expansion Panel (Figure 5−64). The name of the MC
3020D Output Set is then entered on the MPK Devices table (Figure 5−141 on page 5−162). The order of entry on the
Output Set table will correspond to the order of buttons on the CP 3021. For example, the machine listed in row 1 of
the table will be assigned to the first button of the first expansion panel (the first expansion panel on the ribbon wire).

1

Output Set — MC3020D−OUT

Machine Name

VT01

2

VC01

3

VC02

Figure 5−64. CP Output Set used to establish machine names
for centrally−located MC 3021D (example). The correspond-
ing system is shown on page 5−161. See also page 2−76
.

The source of these names is the Machines table (page 5−140).