Configurator

Switcher Description Table

5−37

VM 3000 Installation and Operating Manual

Triton chassis

DIP switch setting

PLvL entry

Red

0000 (decimal 00)

100

In this example, the Green and Blue chassis would also have their Router Address switches set to “0000.”

h.

Conventional TVS/TAS square matrix switchers. For these switchers the hardware switches are usually set as
follows:

Name of level

Physical level no.

Video

1

Left audio

2

Right audio

8

Time code

4

TVS/TAS data matrix forward/reverse level numbers: two levels must be described on the table—a forward level
and a reverse level; for TVS/TAS data matrix switchers the levels have different physical level numbers.

i.

RKX switchers

††

. The physical level number can range from 0 to 99.

j.

Multiple switchers.

An example of a multiple switcher installation is shown on page 2−38.

As discussed in Step 3 above, more than one switcher can be operated by a single VM board; however, this will
require a unique hardware setting on each level to avoid conflicts. For example, you could enter a switcher “MAIN-
ROUT” with levels 1, 2, and 6; and switcher “NEWSROUT” with levels 3, 4, and 5.

Alternatively, by dedicating a separate VM board to each switcher, the same physical level numbers can be used
on different switchers if desired. (See diagram on page 2−39.)

k.

Logical level mapping (two logical levels on one physical level).

An example of logical level mapping is shown on page 2−36.

In these systems, the same physical level number can be used on more than one logical level (i.e., on more than
one row of the Switcher Levels table). For example, you could enter a switcher “MainRout” with Left Audio on
level 2, and with Right Audio also on level 2. This technique can sometimes help reduce overall switcher size, but
it requires special entries to this table and to the Switcher Outputs table as follows:

— the Switcher Levels table must always show the total number of outputs for the entire physical level. For the

example system shown on page 2−36, the matrix entry would be “60 x 60” for the Left logical level, even
though the level is being used as a 60 x 30.
The same applies to the Right logical level; the table entry would be
“60 x 60.”

††

When an RKX and a Grass Valley Crosspoint Bus switcher are entered on this table, an offset of 100 can be used to avoid
having the same level numbers for both switchers. See also footnote marked with “

” on next page.