Control panels – Grass Valley VM 3000 System Controllers v.7.4 User Manual
Page 51
![background image](https://www.manualsdir.com/files/813588/content/doc051.png)
Introduction
1−13
VM 3000 Installation and Operating Manual
CONTROL PANELS
CP 300/310/320/328/330 Control Panels
Connectors:
1, MPK (RS−422/ESbus), looping (9−pin D female)
Power requirements: +5VDC +/− 0.25V @ 600 mA. A wall plug−in power supply is supplied with each 300 series panel that
will be used with 110 VAC 60 Hz power. Panels that are to be used in areas where 220VAC 50Hz power is the norm are not
shipped with any power supply. See page 2−51 for more information.
CP 2002 series control panels
Connectors:
1, MPK (RS−485), looping (RJ45)
1, DC in, Molex Mini−Fit, Jr., 2−pin
Power requirements: 9 VDC / 1.5 A. Use only brick−type power supply, order no. 006 022 811 001 (Euro−plug) or
006 022 811 002 (USA plug)
CP 3000 switcher control panel, MC 3000/3010 machine control panel
Connectors: 1, Data A (RS−422/ESbus), looping (9−pin D female)
Power requirements: +5 VDC
§
CP 3010 expansion panel
Connections to main panel (CP 3000 or MC 3000): flat wire bus
Power requirements: +5 VDC
§
CP 3020, MC 3020D/L, VC 3020 Push Button Control Panels
Connectors:
1, Data A (RS−422/ESbus), looping (9−pin D female)
1, Remote (for expansion panel) (37−pin D female)
Power requirements: 117/220 VAC, 0.25/0.125 A
CP 3021 Push Button Expansion Panel
Connectors:
1, Input (from CP/MC/VC 3020 main panel) (37−pin D female)
1, Output (to next CP 3021) (37−pin D female)
Power requirements: powered from main panel
Max no. of CP 3021 per main panel: 4
CP 3800 Control Panel
Connectors:
1, MPK (RS−422/ESbus), looping (9−pin D female)
Power requirements: 117/220 VAC, 0.25/0.125 A
§
Furnished by CP 3000/3010 chassis power supply. Power supply requirements: 117/220 VAC, 0.5 /0.25 A.