Selecting by output – Grass Valley VM 3000 System Controllers v.7.4 User Manual
Page 630
JNS Physical Diagnostics
15−4
VM 3000 Installation and Operating Manual
Figure 15−4.
The title bar of this MDI child window shows the log file name, and the first two fields of the dialog show the control panel
the user has chosen. To display the associated physical information, select an output, input and level mnemonic. Once these
fields are filled in, select UPDATE to display the “Physical” table.
The Physical table displays the switcher, logical level name, physical inputs and outputs associated with the logical informa-
tion. The user may select to update the table and log manually or automatically by selecting the Manual/Automatic toggle
in the Options menu. Note that multiple lines of information may be displayed for each event if the currently selected input/
output/level uses path−finding.
The contents of this scrolling display can be saved as a CSV (comma delimited) file by selecting the File > Save menu option.
Selecting By Output
When the “Output” field is selected from the “Level Set” table, the “Output Select” dialog is displayed: