Configurator

MPK Devices

5−135

VM 3000 Installation and Operating Manual

X−Y APPLICATION (NO SPLIT PANEL)

128 X 128 control station

MPK bus

VM 3000 “VM1”

CP 3864

“P3864Y1”

128

sources

128

destinations

CP 3864

“P3864X2”

CP 3864

“P3864Y2”

Main Panel

CP 3864

“P3864X1”

Input button 1

Input button 65

Output button 1

Output button 65

Figure 5−114.

P3864X1

CP−3864

00000043

3832−IN

3832−OUT

P3864X2

CP−3864

00000044

P3864Y1

CP−3864

00000045

P3864Y2

CP−3864

00000046

1

MPK Devices

MPK

Expansion

Pass

Board

VM1

Port

Address

Input Sets

Output Sets

Level Set

Overide Set

Sequence Set

2

VM1

KXYZ−LEV

3

VM1

4

VM1

2

Devices

word

In Panel

Out Panel

2

2

2

Note: Assignment of specific CP sets to a panel identifies it as the “main” panel,
i.e., the panel with input button number 1. Beyond the main panel, button
numbering depends on the order in which panels are entered on this table.

Figure 5−115. Entry for system
shown in Figure 5−114.

P3864X1

P3864X1

P3864X1

Device

Type

In this example, the top two CP 3864s are being operated as source panels and the bottom two as destination panels.

The “main” panel is always an input panel. In this example, the top CP 3864 has been selected as the main panel and will
therefore be assigned to specific CP sets. Enter the name of the CP Input and CP Output Sets that will be used to assign inputs
and outputs to all the buttons at this control station. See page 5−58 (CP Input Sets) and page 5−76 (CP Output Sets).

Any additional source panels (CP 3864 “P3864X2” in this example) would refer to the main panel (the top CP 3864) in their
In Panel column. They would use the CP sets assigned to the main panel. The first input expansion panel listed in this table
will have the button numbers immediately following those of the main panel; the next input expansion panel listed will have
the next higher set of button numbers, etc.

All destination panels use the Out Panel column to select the MPK Device name of the main panel; they would use the CP
sets assigned to the main panel. The first output panel listed in this table will have the lowest−numbered set of buttons; the
next output panel listed will have the next higher set of button numbers, etc. MPK Device table entries for other CP 3832/64
applications was discussed on page 5−111 and following.