Configurator
MPK Devices
5−138
VM 3000 Installation and Operating Manual
X−Y Application
In the example shown in Figure 5−120, a CP 3864 is used to select inputs, a CP 3832 is used to select outputs, and a CP 3810
is used to control/status the individual levels of the output selected by the CP 3832. The CP 3810 can thus be used for break-
away switching.
CP 3832
“CP3832”
CP 3810
“CP3810”
32
destinations
64
sources
STATUS
of individual levels
CP 3864
“CP3864”
MPK bus
VM 3000
“VM1”
Figure 5−120.
CP3832
CP−3832
2
00000044
CP3810
CP−3810L
2
00000045
CP3864
CP−3864
2
00000043
3832−IN
3832−OUT
1
MPK Devices
MPK
Expansion
Pass
Board
VM1
Port
Address
Input Sets
Output Sets
Level Set
Overide Set
Sequence Set
2
VM1
KXYZ−LEV
3
VM1
KXYZ−LEV
Devices
word
In Panel
Out Panel
†
Figure 5−121. Entry for system shown in Figure 5−114.
CP3864
CP3864
Device
Type
Notice that the Expansion boxes for all panels are unchecked.
Main panel entries — In this example, a CP 3864 is used to select inputs and is therefore the “main” panel. As such, it is as-
signed specific CP sets, as follows: In the “Input Set” column, enter the name of the CP Input Set that will be used to assign
inputs to the main panel (for more information about CP Input Sets, see page 5−58). In the “Output Set” column, enter the
name of the CP Output Set that will be used to assign Outputs to the destination panel CP 3832 (for more information about
CP Output Sets, see page 5−76).
Destination panel entries — In the Out Panel column, select the name of the main panel.
CP 3810 entries — Select “CP 3810L” as the device type. In the In Panel column, select the name of the main panel.
For operating instructions, see page 6−126.
†
Data not used, but entry must be present to satisfy compiler.