beautypg.com

Category and number input selection, Cat=vtr select, Ab c d – Grass Valley VM 3000 System Controllers v.7.4 User Manual

Page 428: F4 f3 f2 f1

background image

Control Panel Operation

CP 3000

6−8

VN 3000 Installation and Operating Manual

CATEGORY AND NUMBER INPUT SELECTION

The user selects a switcher input by first pressing the desired input category keypad push button. The display menu line will
be cleared and the category name will appear (see Figure 6−8).

VTR

1

CG

2

NET

3

SAT

EJ

VCR

4

CAM

5

REM

6

FILM

7

PTCH

8

STU

9

FS

AUX

TEST

0

MISC

SS

A

B

C

D

TAKE

CHOP

LOCK

PROT

F4

F3

F2

F1

MORE

CLR

MENU

LEV

Figure 6−8. Display after category has been selected.

CAT=VTR SELECT=????

The operator then enters the selection number for the desired input; the display will show the primary mnemonic for the input
after the word “Select.” Additional detail is given on the bottom row, which shows the input mnemonics for the sources
selected on up to four levels. See Figure 6−9. (The appearance and position of each level’s status information is determined
by the CP Level set assigned to the panel).

VTR

1

CG

2

NET

3

SAT

EJ

VCR

4

CAM

5

REM

6

FILM

7

PTCH

8

STU

9

FS

AUX

TEST

0

MISC

SS

A

B

C

D

TAKE

CHOP

LOCK

PROT

F4

F3

F2

F1

MORE

CLR

MENU

LEV

Figure 6−9. Number has been selected. Ready for TAKE to be pressed.

CAT=VTR SELECT=VTR1
VTR1 VT1L VT1R VT1T

Note: If the category entry is ignored, or if the bottom display row stays blank after the selection number is entered,
the category / selection number may not be defined in the CP Input Set (page 5−58) assigned to the panel on the
MPK Devices table (page 5−109).

When TAKE is pressed the command is sent to the switcher matrix. If the TAKE command was successful, the top display
row will be updated to reflect the new input status.

If entry of a password is requested, please see Passwords on page 6−22.

This manual is related to the following products: