beautypg.com

Appendix n, Jupiter ascii communications protocol, In appendix n – Grass Valley VM 3000 System Controllers v.7.4 User Manual

Page 725

background image

N−1

VM 3000 Installation and Operating Manual

Appendix N

Jupiter ASCII Communications Protocol

Revision E − November 10, 2005

Hardware connections for an external computer are shown on page 2−85.

Set−up in the Jupiter Control System File Server includes defining one or more port pairs as being ASCII in the Serial

Protocol Table (page 5−25).

The control computer is identified on the MPK Devices table (page 5−127). You will need to define each port as being

type “Serial”, and give each port a CP Level set, CP Output set, and CP Level set. These sets will determine which levels,

inputs, and outputs are available to each ASCII port to control and status.

The ASCII Computer Interface is assigned to a SC 3000, SI 3000, or VM 3000 serial port pair and uses a simple ASCII

data format defined below. The serial protocol defaults to 9600 Baud, 8 Data Bits, No Parity, and 1 Stop Bit. Baud rates

of 2400, 4800, 19.2K and 38.4K are also user−configurable from the Jupiter Control System File Server. The control port

uses XON (0x11) and XOFF (0x13) to control command pacing if necessary.

All commands are in upper case ASCII. Space (0x20)

characters are optional and will be ignored. Each command is fol-

lowed by a carriage return (0x0D). If a line feed (0x0A)

is included it must follow the carriage return.

The controlling computer must take care to wait for a ZY or ZN response after each command before attempting to send

a subsequent command. Failure to do so will result in a ZN response, and possibly an XOFF condition. If switcher status

is received, wait for all levels to be statused before sending another command.

Here is a key to help you understand the following command descriptions:

OOO −−−> Router Switcher OUTPUT. This corresponds with the “Selection” number defined in this AS-

CII port’s CP Output Set. The range is from 000 to 999. (Previous releases had a range from

000 to 249.)

III −−−−−−−> Router Switcher INPUT. This corresponds with the “Selection” number defined in this ASCII

port’s CP Input Set. (Previous releases had a range from 000 to 249.)

This manual is related to the following products: