Hardware Installation

2−29

VM 3000 Installation and Operating Manual

UTAH SCIENTIFIC PARTY LINE CONNECTION USING UDI−1B

The VM 3000 can be connected to a Utah Scientific Party Line through a UDI−1B Universal Data Interface (see Figure 2−36).
Some UDI−1B units are equipped with a 9−pin RS−422 port; others are equipped with a 25−pin RS−232 port. Either type can
be used.

The protocol for the UDI−1B port must be set at: 9600 baud, 7 data bits, even parity, and 2 stop bits. The UDI−1B must be
equipped with software version 81.4 or later. The UDI−1B “AUX” rotary switch needs to be set to “E” for “PL−160 Mode”
and to enable all mode commands. Refer to the UDI−1B manual for detailed procedures.

Figure 2−36. Connection to Utah Scientific Party Line.

See Figure 2−37 for a description of this cable

Utah 96 protocol

RS−422 port

UDI−1B interface

to Utah Scientific switcher

VM 3000

LAN

See pg

2−46

House time

code

(optional).

See pg.

2−110

Utah Scientific
Party Line

RS−232 port

See Figure 2−38 for a description of these cables

Utah 96 protocol

If the RS−232 port is used it is advisable to use an RS−422 to
RS−232 converter. A Black Box

®

model GJ−IC455B Inter-

face/converter is available from Grass Valley; part no.
05−040935−001.

RS−422/232

converter