Configurator

Tally

5−188

VM 3000 Installation and Operating Manual

Indirect Connection to Transmitter

Please see Figure 5−165.

There are three types of entries on this table: an unqualified output entry; MCS_TLY entries; and production switcher entries.

Unqualified Output

This is the name (“XMIT”) of the routing switcher output leading to the transmitter (or the name of the output leading
to the primary program line). All sources switched to this output will be tallied. The rest of the row remains blank. There
can be more than one unqualified output if desired.

Saturn (“MCS_TLY”) Entries

Similar to those already described (page 5−184), except for the last column. Since the master control switcher is con-
nected indirectly to the transmitter (by re−entry through the routing switcher), each entry must include the name of the
MI 3040/T and the relay number associated with the master control switcher’s tally light.

Production Switcher Entries

Similar to those already described (page 5−186).