Machines, Protocol dependent, Machine control – Grass Valley VM 3000 System Controllers v.7.4 User Manual
Page 350: Delegation groups

Configurator
Machines Table
5−140
VM 3000 Installation and Operating Manual
Machines
hexadecimal
1
Machines
2
VT01
Sony Mch
SI1
1
VT05
Ampex Mch
SI1
7
80A2
Figure 5−124. Machines table for system shown on page 5−142.
Name
Type
Board
Port
Address
Machine
Device
Password
Network Description
Control Panel Sets
Level set
Machines
Protocol Dependent
TCS−1 Device Codes
Status Display Header
Tally
Exclusion
This table is the source for information about machines using Sony or Ampex serial protocol. Data entered here is automatical-
ly made available on the Machine Control table.
§
Important: Row numbers on Jupiter tables are used as the “logical” numbers for devices. Changing the row num-
ber of an existing device (by inserting/deleting a device in the middle of the table, for example) will disrupt con-
trol of the machine, requiring linkages to be reestablished. One way to avoid this interruption is to add new de-
vices at the end of tables.
Name
This column lists the device names of all serial control machines in the system.
This is the source for machine names that appear on the control panels. Although this field will accept eight
characters, you may wish to limit machine names to four since that is the maximum that can be displayed on
the MC 3000’s expansion panel.
§