Data matrix switching, Hardware connections, Software configuration – Grass Valley VM 3000 System Controllers v.7.4 User Manual
Page 109

Hardware Installation
2−37
VM 3000 Installation and Operating Manual
Data Matrix Switching
The Jupiter system can be used to control RS−232, RS−422, and RS−423 data switchers. In a typical application, a Venus data
matrix switcher can be used to route RS−422 machine control signals.
Older model Venus switchers equipped with DM 400 or DM 400A Data Matrix boards require crossover or Y−line cables.
Newer model Venus systems are equipped with the DM 400B Data Matrix boards; these boards have software−configurable
rear−panel pinout functions and do not require crossover or Y−line cables.§
Hardware Connections
For complete information regarding jumper settings and cabling, refer to the technical manual supplied with the data switcher.
Software Configuration
— For DM 400/400A Data Matrix boards, refer to Appendix L.
— For an overview of DM 400B configuration, see page 5−48. Entries are required on the Switcher Description
table (page 5−31), Switcher Input table (page 5−44), Switcher Output table (page 5−51), CP Input Set (page
5−58), and CP Output Set (page 5−76).
§
Type and model of switcher card is shown on front edge of printed circuit board.