beautypg.com

Grass Valley VM 3000 System Controllers v.7.4 User Manual

Page 727

background image

ASCII Protocol

N−3

VM 3000 Installation and Operating Manual

mand, an invalid command format, or an invalid input,

output or level. Invalid inputs, outputs and levels are

logged to the system logger. Also if the system is busy a

ZN will be issued followed by XOFF. When it is again

ready for the next command a XON will be issued. Note

that after the XON, response(s) from the prior command

may be issued (e.g. ZR response(s)).

Router Switcher Control and Status Commands

ZSOOOIIILLLLLLL

Switch Request

This command causes the interface to issue a TAKE

Switch Request to the routing switcher control system and

affects a single routing switcher output. If no levels are

specified, then ALL defined levels are assumed.

Note: Passwords are not honored by automation protocol

handling.

A remote computer can send a command with multiple

Switch Requests (older releases do not have this capabili-

ty). A single command can be up to 180 characters long

which allows switching of from 12−22 outputs (depending

on the specified levels). An example of a multiple Switch

Request follows:

ZS00000112ZS00100212ZS00200312

This example

command would switch outputs 0, 1, and 2

on levels 1 and 2.

ZROOO

Status Request

This command requests current switcher status for a single

output. The response is in the format:

ZROOOIIILLLLLLL

.

If the status for the output is “split”, multiple responses

will be returned.

ZWOOO

Watch Output

This command causes the interface to watch the specified

output for any changes and report such changes. A request

to watch output “999” is a request to watch all defined

This manual is related to the following products: