Default (semi−permanent) linkage – Grass Valley VM 3000 System Controllers v.7.4 User Manual
Page 364

Configurator
Machine Control Table
5−154
VM 3000 Installation and Operating Manual
DEFAULT (SEMI−PERMANENT) LINKAGE
Using the file server, machines can be linked directly to a specific control panel on a semi−permanent basis. An example sys-
tem is shown in Figure 5−132. In this arrangement, only the file server can re−assign control of a machine to another panel.
In other words, the normal linkage function (where machine control follows the routing switcher) is bypassed. The entries
needed on the Machine Control table are shown in Figure 5−133.
“VT01”
“VC01”
“VC02”
“TAPEMC”
MC−3000
VC02
VC01
VT01
SELECT buttons
control lines
software links established
by file server
SI 3000 “SI1”
3
1
2
6
Figure 5−132. Default machine control linkage.
Figure 5−133. Default
linkage entries for sys-
tem shown in Figure
5−132.
1
Machine Control
Device Name
Device Type
Delegation
In/Out
Associated
2
TAPEMC
MC−3000E
Def
VT01(Machine)
3
Mnemonic
TAPEMC
VT01
Sony Mch
In
VC01
Sony Mch
In
VC02
Sony Mch
In
4
Group
Name
VT01
VC01
VC02
TAPEMC
MC−3000E
Def
VC01(Machine)
TAPEMC
5
TAPEMC
MC−3000E
Def
VC02(Machine)
TAPEMC
6
Preroll
2
2
2