Grass Valley VM 3000 System Controllers v.7.4 User Manual
Page 351

Configurator
Machines Table
5−141
VM 3000 Installation and Operating Manual
Type
Device types (shown on a pull−down menu) are limited to the following:
S Sony machine serial protocol
S Ampex machine serial protocol
Note 1: Machines controlled with parallel connections to an MI 3040 are not entered on this table; they are
entered instead on the Machine Control table (pages 5−146 and 5−157).
Note 2: Machines that use TCS or ESbus protocol are entered on the Protocol Dependent Devices table (page
5−143).
Board
Select the name of controller board connected to this machine. The source of these names is the Net-
work Description table (page 5−22).
Port
Number of controller board port connected to this machine. The port must support the necessary proto-
col for this machine (as configured on the Serial Protocol table, page 5−25).
Address
(hex)
Unique serial data bus ID used to select and service this machine, entered in hexadecimal.
(Not to be confused with LAN address entered on Network Description table shown on page 5−22.)
VTR addresses
— not required for Sony “serial” VTRs (as listed on page 2−90).
— required for Ampex “serial” VTRs. The address “80A2” is the usual factory setting. “Daisy−
chaining” Ampex VTRs (not presently recommended) would require changing these addresses in
the VTR itself.