SINGLE−BUS CONTROL

In the example shown in Figure 6−158, a CP 3832 is used to select inputs and a “CP 3810L” is used to control the individual
levels of one output. The CP 3810 can thus be used for breakaway switching.

To find out what output is being controlled by the CP 3810, use the “show destination” procedure for the Main panel. In the
example shown in Figure 6−158, the CP 3832 MENU button would be pressed.

Note: To verify that the CP 3810 has been configured as a “CP 3810L,” press the DEST button. This will display
level names if the panel has been configured as a CP 3810L.

Switching Procedure

PRESET OFF method. See Figure 6−158.

Figure 6−158. Switching with Preset OFF.

Select level(s)

(If no levels are

selected, all levels

will switch.)

PRESET OFF

Select source

32

sources

Levels for 1

destination

[1]

[2]

[3]

PRESET ON method. See Figure 6−159.

Figure 6−159. Switching
with PRESET ON.

PRESET ON

Press TAKE

Select a

single level

(If no levels

are selected,

all levels will

switch.)

Select a source

If desired,select

another level and

[1]

[2]

[3]

[4]

[5]

[6]

source.