beautypg.com

Cp 3810 panel, Hardware installation, Software configuration – Grass Valley VM 3000 System Controllers v.7.4 User Manual

Page 140

background image

Hardware Installation

2−68

VM 3000 Installation and Operating Manual

CP 3810 Panel

The optional CP 3810 panel can be associated with a CP 3832, CP 3864, CP 3808, or CP 3830, providing control of up to
80 outputs. The CP 3810 can also be assigned to one output, providing breakaway (split) switching and/or multi−level status.

Figure 2−82 illustrates a CP 3810 with a CP 3832 panel.

VTR1

VTR2

VTR3

VTR4

VTR5

VTR6

VTR7

VTR8

CAM1

CAM2

CAM3

CAM4

CAM5

CAM6

CAM7

CAM8

BLACK

BARS

TONE

CG−1

SILE
NCE

CG−2

CG−3

CG−4

EBS1

EBS2

TEST1

TEST2

FDL1

FDL2

FDL3

FDL4

Level

Menu

Clear

Prot/
Lock

Pre−

set

Take

CURRENT

PRESET

VTR−001

PLAY/
STOP

PLAY/
STOP

PLAY/
STOP

PLAY/
STOP

PLAY/
STOP

PLAY/
STOP

PLAY/
STOP

PLAY/
STOP

Take/

Set

Take/

Set

Take/

Set

Take/

Set

Take/

Set

Take/

Set

Take/

Set

Take/

Set

Dest

Figure 2−82. CP 3832 (top) with CP 3810 Expansion Panel (below).

VTR−001

PG1

The CP 3810 can be operated in several modes:

— For multi−bus control the destination can be selected on the CP 3810 and the desired source can be selected on

the main panel (CP 3832, CP 3864, CP 3808, or CP 3830). The CP 3810 can display the names of eight destina-
tions. The “page” of eight destinations can be scrolled to display up to 80 possible destinations.

— For single−destination applications, the panel can be configured as a “CP 3810L” and operated with a main

panel or as a stand−alone unit:

S When used with a main panel, the desired destination can be selected on the main panel; the CP 3810

will display the status of eight levels. The “page” of eight levels can be scrolled to display additional
levels. A breakaway switch can be set up and executed with a single Take command.

S When used as a stand−alone status panel, the desired destination is permanently entered on the MPK

table (see Software Configuration below). The CP 3810 will display the status of eight levels. The
“page” of eight levels can be scrolled to display additional levels.

— The CP 3810 can also be used as a limited−function machine control panel, providing Play and Stop com-

mands for VTRs.

— Alternatively, it can be configured as a “CP 3810S,” meaning that the selected outputs will remain selected

until explicitly changed by the operator.

Hardware Installation

Installation of this panel is shown on page 2−50. Note that each CP 3810 panel requires a separate MPK connection.

If desired, the panel hardware can be tested, and window/button brightness adjusted, without being connected to the controller
board (VM/SI−3000). For more information, see Diagnostics Mode on page 6−130.

Software Configuration

Each CP 3810 panel requires a separate entry on the MPK Devices table. See page 5−109.

This manual is related to the following products: