Hardware Installation

2−28

VM 3000 Installation and Operating Manual

NVISION DISTRIBUTION SWITCHER

Certain late−model NVISION switchers can be controlled using the hardware connections shown in Figure 2−34. The proto-
col setting is: 38400 baud, 8 data bits, odd parity, 1 stop bit.

Figure 2−34. Connection to NVISION distribution switcher

See page 2−109 for a description of this cable

NVISION protocol

ESbus port

NVISION switcher

VM 3000

LAN

See pg

2−46

House time

code

(optional).

See pg.

2−110

Odd serial port

PRO−BEL DISTRIBUTION SWITCHER

Pro−bel Eclipse

(SW.P.02)

switchers can be controlled using the hardware connections shown in Figure 2−35. The protocol

setting is: 38400 baud, 8 data bits, odd parity, 1 stop bit.

Note: On the Serial Protocol table (page 5−25) select the “Alpha Imag.” protocol for this switcher.

Figure 2−35. Connection to Pro−bel distribution switcher.

AlphImag protocol

Pro−bel Eclipse switcher

VM 3000

LAN

See pg

2−46

House time

code

(optional).

See pg.

2−110

Refer to the manual

supplied with the

Pro−Bel router for

pinout information.

See Figure 2−33 for
pinout information.

Odd serial port