Control Panel Operation
VGA Display
6−143
VM 3000 Installation and Operating Manual
Note 2: If the cursor mode in the switcher status display will not work, it may be that no CP 3000 was defined
for the VGA on the MPK Devices table (page 5−116).
Force Unprotect / Force Unlock
As a supervisory system, the VGA / CP 3000 can be configured such that it can unprotect or unlock any output
shown on the display.
output and press PROTECT (or LOCK) and TAKE.
— If the panel has not been configured permanently, login to the panel using a 90 level or above password. This
will allow use of the force unprotect/unlock command until logoff.
Important: It is possible for the VGA / CP 3000 to unlock or unprotect outputs regardless of password levels,
including the outputs of an MCS 2000 Master Control Switcher. The outputs will not be re−protected until
the MCS 2000 is reset.
For additional protect/lock information − See page 6−12.
MACHINE & DELEGATION STATUS PAGE
Thomson WXYZ TELEVISION FACILITY CONTROL SYSTEM PAGE: 01
May 10, 1999 MACHINE & DELEGATION STATUS 12:34:56
−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−
MACHINE STATUS LINKAGE MCS STU ENG TAPE
−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−
VT01 STOP StuMC StuMC
VT02
VT03
VT04
VT05
VT06
VT07
VT08
VT09
VC01 STOP StuMC ASSIGNED
VC02 STOP ASSIGNED
VC03
VC04
VC05
Figure 6−173. Machine & delegation
status page (example).
Up to 32
Delegation
groups
A machine and delegation status page (Figure 6−173) can provide a list of all VTRs and other machines listed on the Machine
Control Devices table (page 5−140). The UP and DOWN buttons (or arrow buttons on the CP 3020) will step through addi-
tional pages of machines. Hold the key down to auto−repeat.
Depending on the machine, TMC (Transport Motion Control) status is shown as follows:
OFF NOT REM EJECT STOP STOP−RDY PLAY VAR PLAY FAST F REWIND SHUTTLE + SHUTTLE −