PERMANENT DISPLAY OF MNEMONIC
Front Panel Configuration
Using the front−panel buttons, SlimLine and RP 1/2/3 series UMDs can be configured to display a mnemonic permanently.
For more information, refer to the applicable UMD manual.
Jupiter Configuration
To cause the Jupiter system to display a mnemonic on a permanent basis, use the MPK Devices table to assign an Input Set
to the status display containing only one input name and mnemonic. See Figure 5−100.
UMDSD1
4
00000032
NET−INP
NETMON
KXYZ−LEV
UMD3A
1
MPK Devices
MPK
Expansion
Pass
Board
VM1
Port
Address
Input Sets
Output Sets
Level Set
Overide Set
Sequence Set
Devices
word
In Panel
Out Panel
Device
Type
Figure 5−100.
1
Input Set — NET−INP
Category
Entry
Mnemonic
Logical
2
Net
1
NET
NETIN
Auto
Mnem
Input
The Output Set entry is not used in this application; however, the name of an actual Output Set (or Output) must be entered
to satisfy the compiler.
On the Input Set table, the Input field must be the name of an actual input.