beautypg.com

Permanent display of mnemonic, Front panel configuration, Jupiter configuration – Grass Valley VM 3000 System Controllers v.7.4 User Manual

Page 336: Figure 5−100

background image

Configurator

MPK Devices

5−126

VM 3000 Installation and Operating Manual

PERMANENT DISPLAY OF MNEMONIC

Front Panel Configuration

Using the front−panel buttons, SlimLine and RP 1/2/3 series UMDs can be configured to display a mnemonic permanently.
For more information, refer to the applicable UMD manual.

Jupiter Configuration

To cause the Jupiter system to display a mnemonic on a permanent basis, use the MPK Devices table to assign an Input Set
to the status display containing only one input name and mnemonic. See Figure 5−100.

UMDSD1

4

00000032

NET−INP

NETMON

KXYZ−LEV

UMD3A

1

MPK Devices

MPK

Expansion

Pass

Board

VM1

Port

Address

Input Sets

Output Sets

Level Set

Overide Set

Sequence Set

Devices

word

In Panel

Out Panel

Device

Type

Figure 5−100.

1

Input Set — NET−INP

Category

Entry

Mnemonic

Logical

2

Net

1

NET

NETIN

Auto

Mnem

Input

The Output Set entry is not used in this application; however, the name of an actual Output Set (or Output) must be entered
to satisfy the compiler.

On the Input Set table, the Input field must be the name of an actual input.