SNMP Commands
FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Plasma-ARC
2+3\new_system_mifs_ARC2_latest\SNMP.fm
D E L L C O N F ID E N T IA L – P R E L IM I N A RY 4 / 3 /1 4 - FO R P R O O F O N LY
Syntax
snmp-server community
community
-
string [ro | rw | su]
[
ip-address | ipv6-
address
]
[
mask
mask
| prefix
prefix-length] [
view
view-name]
[type {router
| oob}]
no snmp-server community
community-string [ip-address]
[type {router |
oob}]
Parameters
• community-string—Define the password that permits access to the SNMP
protocol. (Range: 1–20 characters).
•
ro—Specifies read-only access (default)
•
rw—Specifies read-write access
•
su—Specifies SNMP administrator access
•
view
view-name
—Specifies the name of a view configured using the
(no specific order of the command
configurations is imposed on the user). The view defines the objects
available to the community. It is not relevant for su, which has access to
the whole MIB. If unspecified, all the objects, except the community-table
and SNMPv3 user and access tables , are available. (Range: 1–30
characters)
• ip-address—Management station IP address. The default is all IP
addresses. This can be an IPv4 address, IPv6 or IPv6z address. See
•
mask—Specifies the mask of the IPv4 address. This is not a network mask,
but rather a mask that defines which bits of the packet’s source address are
compared to the configured IP address. If unspecified, it defaults to
255.255.255.255. The command returns an error if the mask is specified
without an IPv4 address.
• prefix-length—Specifies the number of bits that comprise the IPv4
address prefix. If unspecified, it defaults to 32. The command returns an
error if the prefix-length is specified without an IPv4 address.
•
type
router
—Indicates whether the IP address is on the out-of-band or in-
band network.