Dell PowerEdge VRTX User Manual
Page 313

Remote Network Monitoring (RMON) Commands
313
FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Plasma-ARC
2+3\new_system_mifs_ARC2_latest\RMON.fm
D E LL CO N F I D E N T IA L – P R E L I M I N A RY 4 / 3 / 14 - F O R PR O O F O N LY
The following table describes significant fields shown in the display:
console# show rmon history 1 other
Sample Set: 1
Interface: gi0/1
Requested samples: 50
Owner: Me
Interval: 1800
Granted samples: 50
Maximum table size: 500
Time
--------------------
Jan 18 2005 21:57:00
Jan 18 2005 21:57:30
Droppe
d
------
3
3
Collisions
----------
0
0
Field
Description
Time
Date and Time the entry is recorded.
Octets
Total number of octets of data (including those in bad packets and
excluding framing bits but including FCS octets) received on the
network.
Packets
Number of packets (including bad packets) received during this
sampling interval.
Broadcast
Number of good packets received during this sampling interval
that were directed to the broadcast address.
Multicast
Number of good packets received during this sampling interval
that were directed to a multicast address. This number does not
include packets addressed to the broadcast address.
Utilization
Best estimate of the mean physical layer network utilization on
this interface during this sampling interval, in hundredths of a
percent.
CRC Align
Number of packets received during this sampling interval that had
a length (excluding framing bits but including FCS octets)
between 64 and 1518 octets, inclusive, but had either a bad Frame
Check Sequence (FCS) with an integral number of octets (FCS
Error) or a bad FCS with a non-integral number of octets
(Alignment Error).