Reload – Dell PowerEdge VRTX User Manual
Page 98

98
System Management Commands
FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Plasma-ARC
2+3\new_system_mifs_ARC2_latest\System_Management.fm
D E L L C O N F ID E N T IA L – P R E L IM I N A RY 4 / 3 /1 4 - FO R P R O O F O N LY
no hostname
Parameters
Name—Specifies the device host name. (Length: 1-160 characters.
Maximum label size for each part of the host name: 58). The hostname must
start with a letter, end with a letter or digit, and have as interior characters
only letters, digits, and hyphens.
Default Configuration
No host name is defined.
Command Mode
Global Configuration mode
Example
The following example specifies the device host name as ‘enterprise’.
console(config)# hostname enterprise
enterprise(config)#
reload
The reload Privileged EXEC mode command reloads the operating system at
a user-specified time.
Syntax
reload [in [hhh:mm | mmm] | at hh:mm [day month]] | cancel]
Parameters
• in hhh:mm | mmm - Schedules a reload of the software to take effect in
the specified minutes or hours and minutes. The reload must take place
within approximately 24 days.
•
at hh:mm - Schedules a reload of the software to take place at the specified
time (using a 24-hour clock). If you specify the month and day, the reload
is scheduled to take place at the specified time and date. If you do not
specify the month and day, the reload takes place at the specified time on