falling —Specifies that if the first sample (after this entry becomes
valid) is less than or equal to falling-threshold, a single falling alarm is
generated.
•
owner
name
—Specifies the name of the person who configured this alarm.
(Valid string)
Default Configuration
The default method type is absolute.
The default startup direction is rising-falling.
If the owner name is not specified, it defaults to an empty string.
Command Mode
Global Configuration mode
Example
The following example configures an alarm with index 1000, MIB object ID
D-Link, sampling interval 360000 seconds (100 hours), rising threshold value
1000000, falling threshold value 1000000, rising threshold event index 10,
falling threshold event index 10, absolute method type and rising-falling
alarm.
console(config)# rmon alarm 1000 1.3.6.1.2.1.2.2.1.10.1 360000
1000000 1000000 10 20