beautypg.com

Zone-1022, Zone-1023, Zone-1024 – Dell POWEREDGE M1000E User Manual

Page 738: Zone-1026

background image

662

Fabric OS Message Reference

53-1001767-01

ZONE-1022

111

ZONE-1022

Message

, [ZONE-1022], ,, INFO, , The effective

configuration has changed to .

Probable Cause

Indicates the effective zone configuration has changed to the name displayed.

Recommended

Action

Verify this zone configuration change was done on purpose. If the new effective zone configuration
is correct, no action is necessary.

Severity

INFO

ZONE-1023

Message

, [ZONE-1023], ,, INFO, , Switch

connected to port (

) is busy. Retry zone merge.

Probable Cause

Indicates the switch is retrying the merge operation. This usually occurs if the switch on the other
side of the port is busy.

Recommended

Action

If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.

Severity

INFO

ZONE-1024

Message

, [ZONE-1024], ,, INFO, ,

message>.

Probable Cause

Indicates the cfgSave command ran successfully. The <Information message> is “cfgSave
completes successfully.”

Recommended

Action

No action is required.

Severity

INFO

ZONE-1026

Message

, [ZONE-1026], ,, INFO, , port

number>

Out of CAM entries.

Probable Cause

Indicates the total number of S_ID entries while creating or adding a zone group exceeds the limit.

Recommended

Action

If hardware zoning enforcement is preferred, edit the zoning database to have zoned PIDs for that
port.

Severity

INFO