616

Fabric OS Message Reference

53-1001767-01

SULB-1018

97

Recommended

Action

Run the slotShow command. If the blade is in a FAULTY state, run the slotPowerOff and
slotPowerOn commands to trigger another firmwareDownload. If the blade is stuck in LOADING
state, remove and re-insert the blade to trigger another firmwareDownload. If the problem persists,
contact your switch service provider.

Severity

ERROR

SULB-1018

Message

, [SULB-1018], , AUDIT, ERROR, ,

Firmwaredownload timed out in slot .

Probable Cause

Indicates there may be an error caused by the blade initialization issue after the new firmware is
downloaded and the blade is rebooted. The error may also be caused by the internal Ethernet issue
or by the persistent storage failure.

Recommended

Action

Run the slotShow command. If the blade is in FAULTY state, run the slotPowerOff and slotPowerOn
commands to trigger another firmwareDownload. If the blade is stuck in LOADING state, remove
and re-insert the blade to trigger another firmwareDownload. If the problem persists, contact your
switch service provider.

Severity

ERROR

SULB-1020

Message

, [SULB-1020], AUDIT, ERROR, , New firmware failed to boot

in slot .

Probable Cause

Indicates the BP blade is still running the old image even though it should reboot with the new
image. This error may indicate that the new image has not been loaded correctly to the specified
blade.

Recommended

Action

Run the slotShow command. If the blade is in a FAULTY state, run the slotPowerOff and
slotPowerOn commands to trigger another firmwareDownload to the blade. If the blade is stuck in
LOADING state, remove and re-insert the blade to trigger another firmwareDownload. If the problem
persists, contact your switch service provider.

Severity

ERROR

SULB-1021

Message

, [SULB-1021],, AUDIT, WARNING, ,

Firmware is being downloaded to the blade in slot .

Probable Cause

Indicates the firmware is being loaded to the indicated blade.

Recommended

Action

Run the firmwareDownloadStatus command to monitor the firmwareDownload progress. After it
finishes, run the firmwareShow command to verify the firmware versions.

Severity