Sec-1104, Sec-1105, Sec-1106 – Dell POWEREDGE M1000E User Manual
Page 602

526
Fabric OS Message Reference
53-1001767-01
SEC-1104
90
Probable Cause
Indicates the switch failed to download a certificate, security database, or policies. This can
happen when the switch does not have enough resources to complete the operation, the fabric has
not stabilized, or the policy database is an invalid format.
Recommended
Action
Wait for fabric to become stable and then retry the operation. If the policy database is in an illegal
format (with configDownload), correct the format and retry the operation.
Severity
ERROR
SEC-1104
Message
primary
Probable Cause
Indicates the switch failed to get either the primary certificate or a primary public key.
Recommended
Action
Verify the primary switch has a valid certificate installed and retry the operation. If a valid
certificate is not installed, install a certificate by following the procedure specified in the Secure
Fabric OS Administrator's Guide.
Severity
ERROR
SEC-1105
Message
disable secure mode on all switches.
Probable Cause
Indicates the switch failed to disable security in the fabric. This could happen if the switch cannot
get the required resources to complete the command, and sending to a remote domain fails or the
remote domain returns an error.
Recommended
Action
Run the secFabricShow to verify that all switches in the fabric are in the ready state. Retry the
command when all switches are READY.
Severity
ERROR
SEC-1106
Message
message data.
Probable Cause
Indicates that some public key infrastructure (PKI) objects on the switch are not in a valid state,
and a signature operation failed.
Recommended
Action
Run the pkiShow command and verify that all PKI objects exist on the switch. If a failure to validate
PKI objects occurs, follow the steps for re-creating PKI objects outlined in the Secure Fabric OS
Administrator's Guide.
Severity
ERROR